Logo do repositório
 
A carregar...
Miniatura
Publicação

Predictive value of heidelberg retina tomograph parameters for the development of glaucoma in the European glaucoma prevention study

Utilize este identificador para referenciar este registo.
Nome:Descrição:Tamanho:Formato: 
am_j_ophthalmol.pdf742.69 KBAdobe PDF Ver/Abrir

Orientador(es)

Resumo(s)

PURPOSE: To determine whether baseline Heidelberg Retina Tomograph (HRT) measurements of the optic disc are associated with the development of open-angle glaucoma (OAG) in individuals with ocular hypertension in the European Glaucoma Prevention Study (EGPS). DESIGN: Retrospective analysis of a prospective, randomized, multicenter, double-masked, controlled clinical trial. METHODS: There were 489 participants in the HRT Ancillary Study to the EGPS. Each baseline HRT parameter was assessed in univariate and multivariate proportional hazards models to determine its association with the development of OAG. Proportional hazards models were used to identify HRT variables that predicted which participants in the EGPS had developed OAG. Development of OAG was based on visual field and/or optic disc changes. RESULTS: At a median follow-up time of about 5 years, 61 participants developed OAG. In multivariate analyses, adjusting for randomization arm, age, baseline IOP, central corneal thickness, pattern standard deviation, and HRT disc area, the following HRT parameters were associated with the development of OAG: the "outside normal limits" classification of the Frederick Mikelberg (FSM) discriminant function (hazard ratio [HR] 2.51, 95% confidence interval [CI]: 1.45-4.35), larger mean cup depth (HR 1.64, 95% CI: 1.21-2.23), cup-to-disc area ratio (HR 1.43, 95% CI: 1.14-1.80), linear cup-to-disc ratio (HR 1.43, 95% CI: 1.13-1.80), cup area (HR 1.33, 95% CI: 1.08-1.64), smaller rim area (HR 1.33, 95% CI: 1.07-1.64), larger cup volume (HR 1.30, 95% CI: 1.05-1.61), smaller rim volume (HR 1.25, 95% CI: 1.01-1.54), larger maximum cup depth (HR 1.18, 95% CI: 1.01-1.36), and cup shape measure (HR 1.18, 95% CI: 1.01-1.36). CONCLUSIONS: Several baseline HRT parameters, alone or in combination with baseline clinical and demographic factors, were significantly associated with the development of OAG among the EGPS participants.

Descrição

Palavras-chave

Glaucoma de Ângulo Aberto Hipertensão Ocular Doenças do Nervo Óptico Técnicas de Diagnóstico Oftalmológico

Contexto Educativo

Citação

Am J Ophthalmol. 2015 Feb;159(2):265-76.e1.

Projetos de investigação

Unidades organizacionais

Fascículo

Editora

Coleções

Licença CC

Métricas Alternativas