A technique to remove a well-fixed titanium-coated RM acetabular cup in revision hip arthroplasty

dc.contributor.authorJudas, F
dc.contributor.authorDias, RF
dc.contributor.authorLucas, FM
dc.date.accessioned2011-11-03T15:46:03Z
dc.date.available2011-11-03T15:46:03Z
dc.date.issued2011
dc.description.abstractA major concern during revision hip arthroplasty is acetabular bone loss and bleeding during the extraction of well-fixed cementless acetabular cup, because no interface exists between the host bone and the cup. Forceful removal of such component using curved gouges and osteotomes often leads to extended bone loss and compromises reimplantation of a new socket. In the following case report, we removed a well-fixed polyethylene titanium-coated RM acetabular cup with 20 years of follow-up, by significant wear of the polyethylene layer. The isoelastic femoral stem was also removed by mechanical failure. We report a technique for removal of the cementless acetabular cup using powered acetabular reamers. The RM cup was sequentially reamed and when the polyethylene layer was thin enough, the remaining cup was removed easily by hand tools. The acetabular bone stock is preserved and the risks of bone fractures and bleeding are minimized. To our knowledge, these principles were applied only in cemented cups. We have used this technique in 10 cases with excellent results and no complications were noted. This is a simple, reproducible, non-costly, non-timing consuming, safe and successful technique to remove well-fixed titanium-coated RM acetabular cups.por
dc.identifier.citationJ Orthop Surg Res. 2011 Jun 20;6:31.por
dc.identifier.urihttp://hdl.handle.net/10400.4/1107
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherBioMedCentralpor
dc.subjectArtroplastia Total da Ancapor
dc.subjectAcetábulopor
dc.subjectPróteses da Ancapor
dc.titleA technique to remove a well-fixed titanium-coated RM acetabular cup in revision hip arthroplastypor
dc.typejournal article
dspace.entity.typePublication
rcaap.rightsopenAccesspor
rcaap.typearticlepor

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
A technique to remove a well-fixed titanium-coated RM acetabular cup in revision hip arthroplasty.pdf
Size:
935.25 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections