Repository logo
 
Publication

Technetium-99m tetrofosmin rest/stress myocardial SPET with a same-day 2-hour protocol: comparison with coronary angiography. A Spanish-Portuguese multicentre clinical trial

dc.contributor.authorMontz, R
dc.contributor.authorPerez-Castejón, MJ
dc.contributor.authorJurado, JA
dc.contributor.authorMartín-Comín, J
dc.contributor.authorEsplugues, E
dc.contributor.authorSalgado, L
dc.contributor.authorVentosa, A
dc.contributor.authorCantinho, G
dc.contributor.authorSá, EP
dc.contributor.authorFonseca, AT
dc.contributor.authorPedroso de Lima, J
dc.date.accessioned2009-05-21T10:25:03Z
dc.date.available2009-05-21T10:25:03Z
dc.date.issued1996
dc.description.abstractTechnetium-99m tetrofosmin (Myoview) has unique properties for myocardial perfusion imaging very early after injection of the tracer. We used a very short same-day rest/stress protocol, to be performed within 2 h and evaluated its diagnostic accuracy. The study included 144 patients from seven Spanish and four Portuguese centres with a diagnosis of uncomplicated coronary artery disease (CAD); 78 patients (54%) had no history of prior myocardial infarction. Patients were injected with </=300 MBq 99mTc-tetrofosmin at rest and </=900 MBq approximately 1 h later at peak exercise. Single-photon emission tomographic (SPET) acquisitions were initiated within 5-30 min post injection. The results were compared with those of coronary angiography (CA). The data of 142 patients were completely evaluable (two with non-evaluable images were excluded). The quality of rest images was excellent or good in 86%, regionally problematic in 7%, poor but well interpretable in 5% and non-evaluable in 2%. The overall sensitivity for the detection of CAD was 93%, the specificity 38% and the accuracy 85%. The localization of defects by SPET in relation to the perfusion territories of stenosed vessels (>/=50%) was achieved with a sensitivity of 64% for the left anterior descending artery, 49% for the left circumflex artery and 86% for the right coronary artery, and an accuracy of 71%, 72% and 73% respectively. Concordance of SPET and CA was 62% for single-vessel disease and 68% for multivessel disease. In conclusion, this Spanish-Portuguese multicentre clinical trial confirmed, in a considerable number of patients who underwent coronary angiography, the feasibility of 99mTc tetrofosmin (Myoview) rest/stress myocardial SPET using a very short protocol (2 h).en
dc.identifier.citationEur J Nucl Med. 1996 Jun;23(6):639-47en
dc.identifier.urihttp://hdl.handle.net/10400.4/512
dc.language.isoengen
dc.rights.uriopenAccessen
dc.subjectAngiografia Coronáriaen
dc.subjectTomografia de Emissão de Fotão Únicoen
dc.subjectCompostos Organofosforadosen
dc.titleTechnetium-99m tetrofosmin rest/stress myocardial SPET with a same-day 2-hour protocol: comparison with coronary angiography. A Spanish-Portuguese multicentre clinical trialen
dc.typejournal article
dspace.entity.typePublication
rcaap.typearticleen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Technetium-99m tetrofosmin ....pdf
Size:
3.74 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.8 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections