This review evaluates the outcomes of intrastromal corneal ring segment (ICRS) implantation for the treatment of keratoconus considering a new grading system based on the preoperative visual impairment of the patient. Additionally, a five-year follow-up analysis of patients with stable and progressive keratoconus is performed in order to assess the long term stability of the surgical procedure. Corrected distance visual acuity decreased statistically significantly in patients with mild keratoconus (P < 0.01) but statistically significantly increased in all other grades (P < 0.05). The improvement in visual acuity and the decrease of keratometric and aberrometric values were stable throughout a long period of time in patients with stable keratoconus. In patients with progressive form keratoconus, a significant improvement was found immediately after the procedure, however clinically relevant regression greater than 3 D was observed at the end of the follow up period.

Descrição

Palavras-chave

Estroma da Córnea Queratocono Próteses e Implantes Acuidade Visual Refracção Ocular Implante de Prótese Procedimentos Cirúrgicos Refractivos

Contexto Educativo

Citação

Middle East Afr J Ophthalmol. 2014 Jan-Mar;21(1):3-9.