Repository logo
 
Publication

p-Phenylenediamine sensitization is more prevalent in central and southern European patch test centres than in Scandinavian: results from a multicentre study

dc.contributor.authorThyssen, JP
dc.contributor.authorAndersen, KE
dc.contributor.authorBruze, M
dc.contributor.authorDiepgen, T
dc.contributor.authorGiménez-Arnau, AM
dc.contributor.authorGonçalo, Margarida
dc.contributor.authorGoossens, A
dc.contributor.authorLe Coz, C
dc.contributor.authorMcFadden, J
dc.contributor.authorRustemeyer, T
dc.contributor.authorWhite, IR
dc.contributor.authorWhite, JM
dc.contributor.authorJohansen, JD
dc.date.accessioned2009-11-19T16:47:22Z
dc.date.available2009-11-19T16:47:22Z
dc.date.issued2009
dc.description.abstractBACKGROUND: Positive patch test reactions to p-phenylenediamine (PPD) are common. PPD is used in oxidative hair dyes and is also present in dark henna temporary 'tattoos'. Cross-sensitization to other contact allergens may occur. Because subjects sensitized to PPD are at risk of clinically severe reactions upon hair dyeing, there is a need for 'current' prevalence data on PPD sensitization. OBJECTIVES: To compare PPD patch test results from dermatitis patients tested between 2003 and 2007 in 10 European patch test centres and to analyse the causes and determine relevance of positive PPD patch test reactions. MATERIALS: Patch testing was performed using PPD (1% free base in petrolatum from Trolab (Almirall Hermal GmbH, Reinbeck, Germany) or Chemotechnique (Malmö, Sweden), equivalent to 0.090 mg/cm(2) in the TRUE test from MEKOS Laboratories AS). Statistical analysis was performed using the chi-squared test. RESULTS: The weighted average prevalence was 4.6% among 21 515 patients. PPD sensitization occurred more often in centres located in Central and Southern Europe than in Scandinavian centres (odds ratio = 2.40; 95% confidence interval = 2.07-2.78). The overall proportion of positive patch test reactions to PPD that were registered as being of either current or 'past' relevance was high (weighted average 53.6% and 20.3%, respectively). Consumer hair dyeing was the most prominent cause of PPD sensitization (weighted average 41.8%). Furthermore, occupational hair dye exposure (10.6%) and cross-sensitization to textile dyes (12.6%) were frequently reported. CONCLUSIONS: PPD sensitization caused by exposure to hair dyes is frequent and remains a present problem for patients visiting contact dermatitis clinics, especially in patch test centres located in Central and Southern Europe.pt
dc.identifier.citationContact Dermatitis. 2009 Jun;60(6):314-9.pt
dc.identifier.urihttp://hdl.handle.net/10400.4/691
dc.language.isoengpt
dc.publisherJohn Wiley & Sonspt
dc.subjectDermatite de Contacto Alérgicapt
dc.subjectDermatite Ocupacionalpt
dc.subjectAlergéniospt
dc.subjectTestes Patchpt
dc.titlep-Phenylenediamine sensitization is more prevalent in central and southern European patch test centres than in Scandinavian: results from a multicentre studypt
dc.typejournal article
dspace.entity.typePublication
rcaap.rightsopenAccesspt
rcaap.typearticlept

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
pphenylenediamine.pdf
Size:
118.74 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.8 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections